Aleta.hr

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • LEGRAND

Technical specifications

Voltage typeAC
Release characteristicD
Rated current20A
Rated voltage400V
Frequency50 - 60Hz
Built-in depth47mm
Number of poles (total)3
Additional equipment possibleYes
Suitable for flush-mounted installationYes
Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V-kA
Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V-kA
Connectable conductor cross section solid-core1.5 - 50mm²
Ambient temperature during operating-25 - 70°C
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V50kA
Pollution degree3
Rated insulation voltage Ui500V
Concurrently switching neutral conductorNo
Over voltage category-
Rated impulse withstand voltage Uimp6kV
Connectable conductor cross section multi-wired1.5 - 35mm²
Width in number of modular spacings4.5
Current limiting class-
Number of protected poles3
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V25kA
Degree of protection (IP)IP20
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

409834 | AUT.OSIG. DX3 3P D20 25KA

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • LEGRAND

Technical specifications

Voltage type

AC

Release characteristic

D

Rated current

20A

Rated voltage

400V

Frequency

50 .. 60Hz

Built-in depth

47mm

Number of poles (total)

3

Additional equipment possible

Suitable for flush-mounted installation

Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V

-kA

Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V

-kA

Connectable conductor cross section solid-core

1.5 .. 50mm²

Ambient temperature during operating

-25 .. 70°C

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V

50kA

Pollution degree

3

Rated insulation voltage Ui

500V

Concurrently switching neutral conductor

Over voltage category

-

Rated impulse withstand voltage Uimp

6kV

Connectable conductor cross section multi-wired

1.5 .. 35mm²

Width in number of modular spacings

4.5

Current limiting class

-

Number of protected poles

3

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V

25kA

Degree of protection (IP)

IP20