Technical specifications

Voltage typeAC
Frequency50 - 60Hz
Release characteristicC
Connectable conductor cross section solid-core1.5 - 50mm²
Rated voltage400V
Degree of protection (IP)IP20
Rated current40A
Built-in depth47mm
Over voltage category-
Number of protected poles2
Additional equipment possibleYes
Suitable for flush-mounted installationYes
Concurrently switching neutral conductorNo
Width in number of modular spacings3
Current limiting class-
Connectable conductor cross section multi-wired1.5 - 35mm²
Pollution degree3
Ambient temperature during operating-25 - 70°C
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V72kA
Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V-kA
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V36kA
Rated impulse withstand voltage Uimp6kV
Number of poles (total)2
Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V-kA
Rated insulation voltage Ui500V
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

410012 | DX3 AUTOM OSIG 2P C40 36KA

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • LEGRAND

Technical specifications

Voltage type

AC

Frequency

50 .. 60Hz

Release characteristic

C

Connectable conductor cross section solid-core

1.5 .. 50mm²

Rated voltage

400V

Degree of protection (IP)

IP20

Rated current

40A

Built-in depth

47mm

Over voltage category

-

Number of protected poles

2

Additional equipment possible

Suitable for flush-mounted installation

Concurrently switching neutral conductor

Width in number of modular spacings

3

Current limiting class

-

Connectable conductor cross section multi-wired

1.5 .. 35mm²

Pollution degree

3

Ambient temperature during operating

-25 .. 70°C

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V

72kA

Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V

-kA

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V

36kA

Rated impulse withstand voltage Uimp

6kV

Number of poles (total)

2

Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V

-kA

Rated insulation voltage Ui

500V