Aleta.hr

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • LEGRAND

Technical specifications

Voltage typeAC
Release characteristicC
Pollution degree3
Over voltage category-
Frequency50 - 60Hz
Built-in depth47mm
Current limiting class-
Rated voltage400V
Rated insulation voltage Ui500V
Rated current50A
Degree of protection (IP)IP20
Number of protected poles2
Number of poles (total)2
Width in number of modular spacings3
Connectable conductor cross section multi-wired1.5 - 35mm²
Connectable conductor cross section solid-core1.5 - 50mm²
Additional equipment possibleYes
Ambient temperature during operating-25 - 70°C
Concurrently switching neutral conductorNo
Suitable for flush-mounted installationYes
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V36kA
Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V-kA
Rated impulse withstand voltage Uimp6kV
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V72kA
Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V-kA
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

410013 | DX3 AUTOM OSIG 2P C50 36KA

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • LEGRAND

Technical specifications

Voltage type

AC

Release characteristic

C

Pollution degree

3

Over voltage category

-

Frequency

50 .. 60Hz

Built-in depth

47mm

Current limiting class

-

Rated voltage

400V

Rated insulation voltage Ui

500V

Rated current

50A

Degree of protection (IP)

IP20

Number of protected poles

2

Number of poles (total)

2

Width in number of modular spacings

3

Connectable conductor cross section multi-wired

1.5 .. 35mm²

Connectable conductor cross section solid-core

1.5 .. 50mm²

Additional equipment possible

Ambient temperature during operating

-25 .. 70°C

Concurrently switching neutral conductor

Suitable for flush-mounted installation

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V

36kA

Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V

-kA

Rated impulse withstand voltage Uimp

6kV

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V

72kA

Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V

-kA

VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.