Technical specifications

Degree of protection (IP)IP20
Voltage typeAC
Width in number of modular spacings6
Rated voltage400V
Built-in depth47mm
Rated current10A
Suitable for flush-mounted installationYes
Release characteristicC
Ambient temperature during operating-25 - 70°C
Connectable conductor cross section multi-wired1.5 - 35mm²
Number of protected poles3
Connectable conductor cross section solid-core1.5 - 50mm²
Number of poles (total)4
Rated impulse withstand voltage Uimp6kV
Rated insulation voltage Ui500V
Current limiting class-
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V72kA
Additional equipment possibleYes
Pollution degree3
Frequency50 - 60Hz
Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V-kA
Over voltage category-
Concurrently switching neutral conductorYes
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V36kA
Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V-kA
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

410033 | DX3 AUTOM OSIG 4P C10 36KA

Main Product Image

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • LEGRAND

Technical specifications

Degree of protection (IP)

IP20

Voltage type

AC

Width in number of modular spacings

6

Rated voltage

400V

Built-in depth

47mm

Rated current

10A

Suitable for flush-mounted installation

Release characteristic

C

Ambient temperature during operating

-25 .. 70°C

Connectable conductor cross section multi-wired

1.5 .. 35mm²

Number of protected poles

3

Connectable conductor cross section solid-core

1.5 .. 50mm²

Number of poles (total)

4

Rated impulse withstand voltage Uimp

6kV

Rated insulation voltage Ui

500V

Current limiting class

-

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V

72kA

Additional equipment possible

Pollution degree

3

Frequency

50 .. 60Hz

Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V

-kA

Over voltage category

-

Concurrently switching neutral conductor

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V

36kA

Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V

-kA