Rated insulation voltage Ui500V
Rated voltage400V
Current limiting class-
Voltage typeAC
Frequency50 - 60Hz
Rated current16A
Width in number of modular spacings6
Pollution degree3
Built-in depth47mm
Degree of protection (IP)IP20
Release characteristicC
Over voltage category-
Connectable conductor cross section solid-core1.5 - 50mm²
Suitable for flush-mounted installationYes
Number of protected poles3
Concurrently switching neutral conductorYes
Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V-kA
Ambient temperature during operating-25 - 70°C
Connectable conductor cross section multi-wired1.5 - 35mm²
Additional equipment possibleYes
Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V-kA
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V72kA
Rated impulse withstand voltage Uimp6kV
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V36kA
Number of poles (total)4
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

410034 | DX3 AUTOM OSIG 4P C16 36KA

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • LEGRAND

Technical specifications

Rated insulation voltage Ui

500V

Rated voltage

400V

Current limiting class

-

Voltage type

AC

Frequency

50 .. 60Hz

Rated current

16A

Width in number of modular spacings

6

Pollution degree

3

Built-in depth

47mm

Degree of protection (IP)

IP20

Release characteristic

C

Over voltage category

-

Connectable conductor cross section solid-core

1.5 .. 50mm²

Suitable for flush-mounted installation

Number of protected poles

3

Concurrently switching neutral conductor

Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V

-kA

Ambient temperature during operating

-25 .. 70°C

Connectable conductor cross section multi-wired

1.5 .. 35mm²

Additional equipment possible

Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V

-kA

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V

72kA

Rated impulse withstand voltage Uimp

6kV

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V

36kA

Number of poles (total)

4