Aleta.hr

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • LEGRAND

Technical specifications

Voltage typeAC
Built-in depth47mm
Release characteristicC
Frequency50 - 60Hz
Width in number of modular spacings6
Degree of protection (IP)IP20
Current limiting class-
Over voltage category-
Rated insulation voltage Ui500V
Connectable conductor cross section solid-core1.5 - 50mm²
Additional equipment possibleYes
Pollution degree3
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V72kA
Connectable conductor cross section multi-wired1.5 - 35mm²
Number of protected poles3
Concurrently switching neutral conductorYes
Number of poles (total)4
Suitable for flush-mounted installationYes
Ambient temperature during operating-25 - 70°C
Rated voltage400V
Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V-kA
Rated current63A
Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V-kA
Rated impulse withstand voltage Uimp6kV
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V36kA
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

410040 | DX3 AUTOM OSIG 4P C63 36KA

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • LEGRAND

Technical specifications

Voltage type

AC

Built-in depth

47mm

Release characteristic

C

Frequency

50 .. 60Hz

Width in number of modular spacings

6

Degree of protection (IP)

IP20

Current limiting class

-

Over voltage category

-

Rated insulation voltage Ui

500V

Connectable conductor cross section solid-core

1.5 .. 50mm²

Additional equipment possible

Pollution degree

3

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V

72kA

Connectable conductor cross section multi-wired

1.5 .. 35mm²

Number of protected poles

3

Concurrently switching neutral conductor

Number of poles (total)

4

Suitable for flush-mounted installation

Ambient temperature during operating

-25 .. 70°C

Rated voltage

400V

Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V

-kA

Rated current

63A

Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V

-kA

Rated impulse withstand voltage Uimp

6kV

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V

36kA

VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.