Aleta.hr

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • LEGRAND

Technical specifications

Rated current10A
Built-in depth47mm
Voltage typeAC
Rated voltage230V
Frequency50 - 60Hz
Rated insulation voltage Ui500V
Current limiting class-
Degree of protection (IP)IP20
Release characteristicC
Pollution degree3
Width in number of modular spacings1.5
Connectable conductor cross section solid-core1.5 - 50mm²
Concurrently switching neutral conductorNo
Number of protected poles1
Suitable for flush-mounted installationYes
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V50kA
Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V-kA
Rated impulse withstand voltage Uimp6kV
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V-kA
Additional equipment possibleYes
Connectable conductor cross section multi-wired1.5 - 35mm²
Number of poles (total)1
Ambient temperature during operating-25 - 70°C
Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V-kA
Over voltage category-
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

410134 | AUT.OSIG. DX3 1P C10 50KA

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • LEGRAND

Technical specifications

Rated current

10A

Built-in depth

47mm

Voltage type

AC

Rated voltage

230V

Frequency

50 .. 60Hz

Rated insulation voltage Ui

500V

Current limiting class

-

Degree of protection (IP)

IP20

Release characteristic

C

Pollution degree

3

Width in number of modular spacings

1.5

Connectable conductor cross section solid-core

1.5 .. 50mm²

Concurrently switching neutral conductor

Number of protected poles

1

Suitable for flush-mounted installation

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V

50kA

Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V

-kA

Rated impulse withstand voltage Uimp

6kV

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V

-kA

Additional equipment possible

Connectable conductor cross section multi-wired

1.5 .. 35mm²

Number of poles (total)

1

Ambient temperature during operating

-25 .. 70°C

Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V

-kA

Over voltage category

-

VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.