Aleta.hr

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • LEGRAND

Technical specifications

Concurrently switching neutral conductorNo
Built-in depth47mm
Rated voltage230V
Additional equipment possibleYes
Number of protected poles1
Pollution degree3
Connectable conductor cross section multi-wired1.5 - 35mm²
Rated current20A
Width in number of modular spacings1.5
Connectable conductor cross section solid-core1.5 - 50mm²
Frequency50 - 60Hz
Current limiting class-
Release characteristicD
Ambient temperature during operating-25 - 70°C
Voltage typeAC
Suitable for flush-mounted installationYes
Degree of protection (IP)IP20
Over voltage category-
Rated insulation voltage Ui500V
Number of poles (total)1
Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V-kA
Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V-kA
Rated impulse withstand voltage Uimp6kV
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V-kA
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V50kA
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

410188 | AUT.OSIG. DX3 1P D20 50KA

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • LEGRAND

Technical specifications

Concurrently switching neutral conductor

Built-in depth

47mm

Rated voltage

230V

Additional equipment possible

Number of protected poles

1

Pollution degree

3

Connectable conductor cross section multi-wired

1.5 .. 35mm²

Rated current

20A

Width in number of modular spacings

1.5

Connectable conductor cross section solid-core

1.5 .. 50mm²

Frequency

50 .. 60Hz

Current limiting class

-

Release characteristic

D

Ambient temperature during operating

-25 .. 70°C

Voltage type

AC

Suitable for flush-mounted installation

Degree of protection (IP)

IP20

Over voltage category

-

Rated insulation voltage Ui

500V

Number of poles (total)

1

Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V

-kA

Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V

-kA

Rated impulse withstand voltage Uimp

6kV

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V

-kA

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V

50kA