Aleta.hr
Main Product Image

410201 | AUT.OSIG. DX3 2P D20 50KA

Code: 1778663

ManufacturerLegrand
Catalog number410201
EAN code3245064102018

















Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • LEGRAND

Technical specifications

Degree of protection (IP)IP20
Voltage typeAC
Suitable for flush-mounted installationYes
Rated current20A
Rated voltage400V
Width in number of modular spacings3
Built-in depth47mm
Release characteristicD
Ambient temperature during operating-25 - 70°C
Connectable conductor cross section multi-wired1.5 - 35mm²
Number of protected poles2
Rated impulse withstand voltage Uimp6kV
Rated insulation voltage Ui500V
Number of poles (total)2
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V100kA
Current limiting class-
Additional equipment possibleYes
Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V-kA
Frequency50 - 60Hz
Pollution degree3
Concurrently switching neutral conductorNo
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V50kA
Connectable conductor cross section solid-core1.5 - 50mm²
Over voltage category-
Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V-kA
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

410201 | AUT.OSIG. DX3 2P D20 50KA

Main Product Image

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • LEGRAND

Technical specifications

Degree of protection (IP)

IP20

Voltage type

AC

Suitable for flush-mounted installation

Rated current

20A

Rated voltage

400V

Width in number of modular spacings

3

Built-in depth

47mm

Release characteristic

D

Ambient temperature during operating

-25 .. 70°C

Connectable conductor cross section multi-wired

1.5 .. 35mm²

Number of protected poles

2

Rated impulse withstand voltage Uimp

6kV

Rated insulation voltage Ui

500V

Number of poles (total)

2

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V

100kA

Current limiting class

-

Additional equipment possible

Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V

-kA

Frequency

50 .. 60Hz

Pollution degree

3

Concurrently switching neutral conductor

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V

50kA

Connectable conductor cross section solid-core

1.5 .. 50mm²

Over voltage category

-

Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V

-kA

*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.