Aleta.hr

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • LEGRAND

Technical specifications

Voltage typeAC
Rated voltage400V
Rated current32A
Built-in depth47mm
Number of protected poles2
Over voltage category-
Frequency50 - 60Hz
Current limiting class-
Rated insulation voltage Ui500V
Concurrently switching neutral conductorNo
Width in number of modular spacings3
Release characteristicD
Degree of protection (IP)IP20
Pollution degree3
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V50kA
Connectable conductor cross section solid-core1.5 - 50mm²
Suitable for flush-mounted installationYes
Connectable conductor cross section multi-wired1.5 - 35mm²
Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V-kA
Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V-kA
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V100kA
Number of poles (total)2
Ambient temperature during operating-25 - 70°C
Additional equipment possibleYes
Rated impulse withstand voltage Uimp6kV
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

410203 | AUT.OSIG. DX3 2P D32 50KA

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • LEGRAND

Technical specifications

Voltage type

AC

Rated voltage

400V

Rated current

32A

Built-in depth

47mm

Number of protected poles

2

Over voltage category

-

Frequency

50 .. 60Hz

Current limiting class

-

Rated insulation voltage Ui

500V

Concurrently switching neutral conductor

Width in number of modular spacings

3

Release characteristic

D

Degree of protection (IP)

IP20

Pollution degree

3

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V

50kA

Connectable conductor cross section solid-core

1.5 .. 50mm²

Suitable for flush-mounted installation

Connectable conductor cross section multi-wired

1.5 .. 35mm²

Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V

-kA

Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V

-kA

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V

100kA

Number of poles (total)

2

Ambient temperature during operating

-25 .. 70°C

Additional equipment possible

Rated impulse withstand voltage Uimp

6kV