Aleta.hr

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • LEGRAND

Technical specifications

Current limiting class-
Voltage typeAC
Rated current50A
Rated voltage400V
Release characteristicD
Rated insulation voltage Ui500V
Pollution degree3
Degree of protection (IP)IP20
Built-in depth47mm
Frequency50 - 60Hz
Width in number of modular spacings6
Over voltage category-
Concurrently switching neutral conductorYes
Number of protected poles3
Suitable for flush-mounted installationYes
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V50kA
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V100kA
Connectable conductor cross section multi-wired1.5 - 35mm²
Ambient temperature during operating-25 - 70°C
Rated impulse withstand voltage Uimp6kV
Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V-kA
Additional equipment possibleYes
Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V-kA
Connectable conductor cross section solid-core1.5 - 50mm²
Number of poles (total)4
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

410231 | AUT.OSIG. DX3 4P D50 50KA

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • LEGRAND

Technical specifications

Current limiting class

-

Voltage type

AC

Rated current

50A

Rated voltage

400V

Release characteristic

D

Rated insulation voltage Ui

500V

Pollution degree

3

Degree of protection (IP)

IP20

Built-in depth

47mm

Frequency

50 .. 60Hz

Width in number of modular spacings

6

Over voltage category

-

Concurrently switching neutral conductor

Number of protected poles

3

Suitable for flush-mounted installation

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V

50kA

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V

100kA

Connectable conductor cross section multi-wired

1.5 .. 35mm²

Ambient temperature during operating

-25 .. 70°C

Rated impulse withstand voltage Uimp

6kV

Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V

-kA

Additional equipment possible

Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V

-kA

Connectable conductor cross section solid-core

1.5 .. 50mm²

Number of poles (total)

4