Aleta.hr

Details

  • Circuit breakers and fuses
  • Earth leakage circuit breaker
  • 1 KOM
  • LEGRAND

Technical specifications

Built-in depth44mm
Voltage typeAC
Current limiting class3
Release characteristicC
Degree of protection (IP)IP20
Rated fault current0.03A
Surge current capacity0.25kA
Leakage current typeA
Connectable conductor cross section solid-core0.75 - 16mm²
Rated current32A
Frequency50 Hz
Rated insulation voltage Ui-V
Rated voltage230V
Number of protected poles1
Width in number of modular spacings2
Pollution degree2
Rated short-circuit breaking capacity according to IEC 60947-26kA
Suitable for flush-mounted installationYes
Concurrently switching neutral conductorYes
Over voltage category-
Rated impulse withstand voltage Uimp-kV
Rated short-circuit breaking capacity Icn according to EN 61009-16kA
Anti-nuisance tripping versionNo
With interlocking deviceYes
Connectable conductor cross section multi-wired0.75 - 10mm²
Ambient temperature during operating- - -°C
Number of poles (total)2
Rated short-circuit breaking capacity according to EN 610096kA
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

411064 | KZS DX3 1P+N C32 10KA A 30MA

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Circuit breakers and fuses
  • Earth leakage circuit breaker
  • 1 KOM
  • LEGRAND

Technical specifications

Built-in depth

44mm

Voltage type

AC

Current limiting class

3

Release characteristic

C

Degree of protection (IP)

IP20

Rated fault current

0.03A

Surge current capacity

0.25kA

Leakage current type

A

Connectable conductor cross section solid-core

0.75 .. 16mm²

Rated current

32A

Frequency

50 Hz

Rated insulation voltage Ui

-V

Rated voltage

230V

Number of protected poles

1

Width in number of modular spacings

2

Pollution degree

2

Rated short-circuit breaking capacity according to IEC 60947-2

6kA

Suitable for flush-mounted installation

Concurrently switching neutral conductor

Over voltage category

-

Rated impulse withstand voltage Uimp

-kV

Rated short-circuit breaking capacity Icn according to EN 61009-1

6kA

Anti-nuisance tripping version

With interlocking device

Connectable conductor cross section multi-wired

0.75 .. 10mm²

Ambient temperature during operating

- .. -°C

Number of poles (total)

2

Rated short-circuit breaking capacity according to EN 61009

6kA

VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.