Aleta.hr

Details

  • Circuit breakers and fuses
  • Earth leakage circuit breaker
  • 1 KOM
  • LEGRAND

Technical specifications

Rated fault current0.3A
Over voltage category-
Release characteristicB
Concurrently switching neutral conductorYes
Rated current10A
Connectable conductor cross section multi-wired- - -mm²
Rated insulation voltage Ui-V
Frequency50 Hz
Suitable for flush-mounted installationYes
Degree of protection (IP)IP20
Number of protected poles4
Connectable conductor cross section solid-core- - -mm²
Width in number of modular spacings4
Surge current capacity0.25kA
Pollution degree2
Rated voltage400V
Built-in depth44mm
Voltage typeAC
Leakage current typeA
Current limiting class1
Rated short-circuit breaking capacity according to IEC 60947-210kA
Rated short-circuit breaking capacity according to EN 610096kA
With interlocking deviceYes
Rated short-circuit breaking capacity Icn according to EN 61009-16kA
Number of poles (total)4
Anti-nuisance tripping versionNo
Rated impulse withstand voltage Uimp-kV
Ambient temperature during operating- - -°C
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

411228 | KZS DX3 4P B10 10KA A 300MA

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Circuit breakers and fuses
  • Earth leakage circuit breaker
  • 1 KOM
  • LEGRAND

Technical specifications

Rated fault current

0.3A

Over voltage category

-

Release characteristic

B

Concurrently switching neutral conductor

Rated current

10A

Connectable conductor cross section multi-wired

- .. -mm²

Rated insulation voltage Ui

-V

Frequency

50 Hz

Suitable for flush-mounted installation

Degree of protection (IP)

IP20

Number of protected poles

4

Connectable conductor cross section solid-core

- .. -mm²

Width in number of modular spacings

4

Surge current capacity

0.25kA

Pollution degree

2

Rated voltage

400V

Built-in depth

44mm

Voltage type

AC

Leakage current type

A

Current limiting class

1

Rated short-circuit breaking capacity according to IEC 60947-2

10kA

Rated short-circuit breaking capacity according to EN 61009

6kA

With interlocking device

Rated short-circuit breaking capacity Icn according to EN 61009-1

6kA

Number of poles (total)

4

Anti-nuisance tripping version

Rated impulse withstand voltage Uimp

-kV

Ambient temperature during operating

- .. -°C

VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.