Aleta.hr

Details

  • Circuit breakers and fuses
  • Earth leakage circuit breaker
  • 1 KOM
  • LEGRAND

Technical specifications

Rated current13A
Voltage typeAC
Surge current capacity3kA
Over voltage category-
Rated voltage230V
Current limiting class3
Built-in depth44mm
Rated fault current0.03A
Release characteristicC
Rated insulation voltage Ui-V
Leakage current typeA
Pollution degree2
Width in number of modular spacings4
Frequency50 Hz
Degree of protection (IP)IP20
Number of protected poles1
Ambient temperature during operating- - -°C
Connectable conductor cross section solid-core0.75 - 16mm²
Number of poles (total)2
Concurrently switching neutral conductorYes
With interlocking deviceYes
Suitable for flush-mounted installationYes
Connectable conductor cross section multi-wired0.75 - 10mm²
Rated short-circuit breaking capacity according to IEC 60947-210kA
Anti-nuisance tripping versionNo
Rated short-circuit breaking capacity according to EN 6100910kA
Rated impulse withstand voltage Uimp-kV
Rated short-circuit breaking capacity Icn according to EN 61009-110kA
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

411311 | KZS DX3 1P+N C13 10KA A-G 30MA

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Circuit breakers and fuses
  • Earth leakage circuit breaker
  • 1 KOM
  • LEGRAND

Technical specifications

Rated current

13A

Voltage type

AC

Surge current capacity

3kA

Over voltage category

-

Rated voltage

230V

Current limiting class

3

Built-in depth

44mm

Rated fault current

0.03A

Release characteristic

C

Rated insulation voltage Ui

-V

Leakage current type

A

Pollution degree

2

Width in number of modular spacings

4

Frequency

50 Hz

Degree of protection (IP)

IP20

Number of protected poles

1

Ambient temperature during operating

- .. -°C

Connectable conductor cross section solid-core

0.75 .. 16mm²

Number of poles (total)

2

Concurrently switching neutral conductor

With interlocking device

Suitable for flush-mounted installation

Connectable conductor cross section multi-wired

0.75 .. 10mm²

Rated short-circuit breaking capacity according to IEC 60947-2

10kA

Anti-nuisance tripping version

Rated short-circuit breaking capacity according to EN 61009

10kA

Rated impulse withstand voltage Uimp

-kV

Rated short-circuit breaking capacity Icn according to EN 61009-1

10kA

VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.