Aleta.hr

Details

  • Circuit breakers and fuses
  • Earth leakage circuit breaker
  • 1 KOM
  • LEGRAND

Technical specifications

Surge current capacity3kA
Rated voltage230V
Rated insulation voltage Ui-V
Release characteristicC
Pollution degree2
Width in number of modular spacings4
Rated fault current0.03A
Built-in depth44mm
Voltage typeAC
Over voltage category-
Current limiting class3
Rated current25A
Leakage current typeA
Number of protected poles1
Connectable conductor cross section solid-core0.75 - 16mm²
Concurrently switching neutral conductorYes
Rated short-circuit breaking capacity Icn according to EN 61009-110kA
With interlocking deviceYes
Connectable conductor cross section multi-wired0.75 - 10mm²
Suitable for flush-mounted installationYes
Number of poles (total)2
Rated short-circuit breaking capacity according to IEC 60947-210kA
Ambient temperature during operating- - -°C
Anti-nuisance tripping versionNo
Rated impulse withstand voltage Uimp-kV
Degree of protection (IP)IP20
Rated short-circuit breaking capacity according to EN 6100910kA
Frequency50 Hz
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

411314 | KZS DX3 1P+N C25 10KA A-G 30MA

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Circuit breakers and fuses
  • Earth leakage circuit breaker
  • 1 KOM
  • LEGRAND

Technical specifications

Surge current capacity

3kA

Rated voltage

230V

Rated insulation voltage Ui

-V

Release characteristic

C

Pollution degree

2

Width in number of modular spacings

4

Rated fault current

0.03A

Built-in depth

44mm

Voltage type

AC

Over voltage category

-

Current limiting class

3

Rated current

25A

Leakage current type

A

Number of protected poles

1

Connectable conductor cross section solid-core

0.75 .. 16mm²

Concurrently switching neutral conductor

Rated short-circuit breaking capacity Icn according to EN 61009-1

10kA

With interlocking device

Connectable conductor cross section multi-wired

0.75 .. 10mm²

Suitable for flush-mounted installation

Number of poles (total)

2

Rated short-circuit breaking capacity according to IEC 60947-2

10kA

Ambient temperature during operating

- .. -°C

Anti-nuisance tripping version

Rated impulse withstand voltage Uimp

-kV

Degree of protection (IP)

IP20

Rated short-circuit breaking capacity according to EN 61009

10kA

Frequency

50 Hz

VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.