Aleta.hr

Details

  • Earthing, lightning and surge protection
  • Surge protection device for power supply systems
  • 1 KOM
  • LEGRAND

Technical specifications

Voltage protection level2.2kV
Mounting methodDIN rail (top hat rail) 35 mm
Signalling at the deviceOptic
Max. continuous voltage DC-V
With remote signalling contactYes
Construction size8 modular spacing
Max. continuous voltage AC320V
Nominal voltage AC400V
Nominal discharge surge current (8/20)20kA
Voltage protection level L-N2.3kV
Category type 2Yes
Number of conductors (without earthing)4
Nominal voltage DC-V
System configuration TN-SNo
Integrated backup fuseNo
Degree of protection (IP)IP20
Max. PV-voltage-V
System configuration DCNo
Voltage protection level N-PE1.4kV
System configuration ITNo
System configuration TNNo
Max. conductor cross section solid (solid, stranded)35mm²
System configuration TN-CNo
Max. conductor cross section flexible (fine-strand)25mm²
System configuration otherNo
Short-circuit breaking capacity (Isccr)-kA
System configuration TTYes
System configuration TN-C-SNo
Max. discharge surge current (8/20)-kA
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

412267 | ODV PREN KL2 40KA D MOD 4P +SD

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Earthing, lightning and surge protection
  • Surge protection device for power supply systems
  • 1 KOM
  • LEGRAND

Technical specifications

Voltage protection level

2.2kV

Mounting method

DIN rail (top hat rail) 35 mm

Signalling at the device

Optic

Max. continuous voltage DC

-V

With remote signalling contact

Construction size

8 modular spacing

Max. continuous voltage AC

320V

Nominal voltage AC

400V

Nominal discharge surge current (8/20)

20kA

Voltage protection level L-N

2.3kV

Category type 2

Number of conductors (without earthing)

4

Nominal voltage DC

-V

System configuration TN-S

Integrated backup fuse

Degree of protection (IP)

IP20

Max. PV-voltage

-V

System configuration DC

Voltage protection level N-PE

1.4kV

System configuration IT

System configuration TN

Max. conductor cross section solid (solid, stranded)

35mm²

System configuration TN-C

Max. conductor cross section flexible (fine-strand)

25mm²

System configuration other

Short-circuit breaking capacity (Isccr)

-kA

System configuration TT

System configuration TN-C-S

Max. discharge surge current (8/20)

-kA

VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.