Aleta.hr

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • LEGRAND

Technical specifications

Frequency- - -Hz
Rated current6A
Rated voltage800V
Voltage typeDC
Built-in depth44mm
Rated insulation voltage Ui1000V
Concurrently switching neutral conductorNo
Release characteristicB
Over voltage category-
Degree of protection (IP)IP20
Width in number of modular spacings2
Number of protected poles2
Current limiting class-
Pollution degree2
Suitable for flush-mounted installationYes
Connectable conductor cross section multi-wired- - -mm²
Connectable conductor cross section solid-core- - -mm²
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V-kA
Additional equipment possibleYes
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V-kA
Rated impulse withstand voltage Uimp8kV
Number of poles (total)2
Ambient temperature during operating- - -°C
Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V-kA
Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V-kA
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

414424 | OSIG. DC 2P B6 800V DC

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • LEGRAND

Technical specifications

Frequency

- .. -Hz

Rated current

6A

Rated voltage

800V

Voltage type

DC

Built-in depth

44mm

Rated insulation voltage Ui

1000V

Concurrently switching neutral conductor

Release characteristic

B

Over voltage category

-

Degree of protection (IP)

IP20

Width in number of modular spacings

2

Number of protected poles

2

Current limiting class

-

Pollution degree

2

Suitable for flush-mounted installation

Connectable conductor cross section multi-wired

- .. -mm²

Connectable conductor cross section solid-core

- .. -mm²

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V

-kA

Additional equipment possible

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V

-kA

Rated impulse withstand voltage Uimp

8kV

Number of poles (total)

2

Ambient temperature during operating

- .. -°C

Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V

-kA

Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V

-kA