Aleta.hr
Main Product Image

414428 | OSIG. DC 2P B16 800V DC

Code: 1779387

ManufacturerLegrand
Catalog number414428
EAN code3245064144285

















Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • LEGRAND

Technical specifications

Degree of protection (IP)IP20
Voltage typeDC
Suitable for flush-mounted installationYes
Width in number of modular spacings2
Rated voltage800V
Rated current16A
Built-in depth44mm
Ambient temperature during operating- - -°C
Release characteristicB
Connectable conductor cross section multi-wired- - -mm²
Connectable conductor cross section solid-core- - -mm²
Number of protected poles2
Rated insulation voltage Ui1000V
Rated impulse withstand voltage Uimp8kV
Number of poles (total)2
Current limiting class-
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V-kA
Additional equipment possibleYes
Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V-kA
Pollution degree2
Frequency- - -Hz
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V-kA
Concurrently switching neutral conductorNo
Over voltage category-
Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V-kA
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

414428 | OSIG. DC 2P B16 800V DC

Main Product Image

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • LEGRAND

Technical specifications

Degree of protection (IP)

IP20

Voltage type

DC

Suitable for flush-mounted installation

Width in number of modular spacings

2

Rated voltage

800V

Rated current

16A

Built-in depth

44mm

Ambient temperature during operating

- .. -°C

Release characteristic

B

Connectable conductor cross section multi-wired

- .. -mm²

Connectable conductor cross section solid-core

- .. -mm²

Number of protected poles

2

Rated insulation voltage Ui

1000V

Rated impulse withstand voltage Uimp

8kV

Number of poles (total)

2

Current limiting class

-

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V

-kA

Additional equipment possible

Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V

-kA

Pollution degree

2

Frequency

- .. -Hz

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V

-kA

Concurrently switching neutral conductor

Over voltage category

-

Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V

-kA

*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.