Aleta.hr

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 12 KOM
  • LEGRAND

Technical specifications

Ambient temperature during operating- - -°C
Width in number of modular spacings1
Rated voltage230V
Suitable for flush-mounted installationYes
Number of protected poles1
Concurrently switching neutral conductorNo
Built-in depth44mm
Degree of protection (IP)IP20
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V6kA
Release characteristicB
Additional equipment possibleNo
Current limiting class3
Number of poles (total)1
Over voltage category-
Pollution degree2
Frequency50 - 60Hz
Rated current20A
Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V6kA
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V-kA
Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V-kA
Rated insulation voltage Ui500V
Connectable conductor cross section solid-core- - -mm²
Voltage typeAC
Connectable conductor cross section multi-wired- - -mm²
Rated impulse withstand voltage Uimp4kV
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

419137 | RX3 AUTOM OSIG 1P B 20A 6KA 1M

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 12 KOM
  • LEGRAND

Technical specifications

Ambient temperature during operating

- .. -°C

Width in number of modular spacings

1

Rated voltage

230V

Suitable for flush-mounted installation

Number of protected poles

1

Concurrently switching neutral conductor

Built-in depth

44mm

Degree of protection (IP)

IP20

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V

6kA

Release characteristic

B

Additional equipment possible

Current limiting class

3

Number of poles (total)

1

Over voltage category

-

Pollution degree

2

Frequency

50 .. 60Hz

Rated current

20A

Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V

6kA

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V

-kA

Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V

-kA

Rated insulation voltage Ui

500V

Connectable conductor cross section solid-core

- .. -mm²

Voltage type

AC

Connectable conductor cross section multi-wired

- .. -mm²

Rated impulse withstand voltage Uimp

4kV