Aleta.hr

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 12 KOM
  • LEGRAND

Technical specifications

Built-in depth44mm
Voltage typeAC
Rated current50A
Current limiting class3
Rated voltage230V
Degree of protection (IP)IP20
Frequency50 - 60Hz
Number of protected poles1
Release characteristicB
Width in number of modular spacings1
Over voltage category-
Rated insulation voltage Ui500V
Pollution degree2
Suitable for flush-mounted installationYes
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V6kA
Ambient temperature during operating- - -°C
Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V6kA
Number of poles (total)1
Connectable conductor cross section solid-core- - -mm²
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V-kA
Connectable conductor cross section multi-wired- - -mm²
Concurrently switching neutral conductorNo
Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V-kA
Additional equipment possibleNo
Rated impulse withstand voltage Uimp4kV
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

419141 | RX3 AUTOM OSIG 1P B 50A 6KA 1M

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 12 KOM
  • LEGRAND

Technical specifications

Built-in depth

44mm

Voltage type

AC

Rated current

50A

Current limiting class

3

Rated voltage

230V

Degree of protection (IP)

IP20

Frequency

50 .. 60Hz

Number of protected poles

1

Release characteristic

B

Width in number of modular spacings

1

Over voltage category

-

Rated insulation voltage Ui

500V

Pollution degree

2

Suitable for flush-mounted installation

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V

6kA

Ambient temperature during operating

- .. -°C

Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V

6kA

Number of poles (total)

1

Connectable conductor cross section solid-core

- .. -mm²

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V

-kA

Connectable conductor cross section multi-wired

- .. -mm²

Concurrently switching neutral conductor

Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V

-kA

Additional equipment possible

Rated impulse withstand voltage Uimp

4kV

VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.