Technical specifications

Width in number of modular spacings2
Built-in depth44mm
Rated voltage400V
Current limiting class3
Concurrently switching neutral conductorNo
Rated current25A
Number of protected poles2
Suitable for flush-mounted installationYes
Degree of protection (IP)IP20
Rated insulation voltage Ui500V
Frequency50 - 60Hz
Connectable conductor cross section solid-core- - -mm²
Pollution degree2
Voltage typeAC
Release characteristicB
Over voltage category-
Connectable conductor cross section multi-wired- - -mm²
Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V6kA
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V10kA
Ambient temperature during operating- - -°C
Number of poles (total)2
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V6kA
Rated impulse withstand voltage Uimp4kV
Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V10kA
Additional equipment possibleNo
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

419160 | RX3 AUTOM OSIG 2P B 25A 6KA 2M

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 6 KOM
  • LEGRAND

Technical specifications

Width in number of modular spacings

2

Built-in depth

44mm

Rated voltage

400V

Current limiting class

3

Concurrently switching neutral conductor

Rated current

25A

Number of protected poles

2

Suitable for flush-mounted installation

Degree of protection (IP)

IP20

Rated insulation voltage Ui

500V

Frequency

50 .. 60Hz

Connectable conductor cross section solid-core

- .. -mm²

Pollution degree

2

Voltage type

AC

Release characteristic

B

Over voltage category

-

Connectable conductor cross section multi-wired

- .. -mm²

Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V

6kA

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V

10kA

Ambient temperature during operating

- .. -°C

Number of poles (total)

2

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V

6kA

Rated impulse withstand voltage Uimp

4kV

Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V

10kA

Additional equipment possible