Aleta.hr
Main Product Image

419164 | RX3 AUTOM OSIG 2P B 63A 6KA 2M

Code: 1780063

ManufacturerLegrand
Catalog number419164
EAN code3414970367204

















Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 6 KOM
  • LEGRAND

Technical specifications

Degree of protection (IP)IP20
Voltage typeAC
Suitable for flush-mounted installationYes
Width in number of modular spacings2
Rated voltage400V
Rated current63A
Built-in depth44mm
Release characteristicB
Ambient temperature during operating- - -°C
Number of protected poles2
Connectable conductor cross section multi-wired- - -mm²
Connectable conductor cross section solid-core- - -mm²
Rated impulse withstand voltage Uimp4kV
Number of poles (total)2
Rated insulation voltage Ui500V
Current limiting class3
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V10kA
Additional equipment possibleNo
Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V10kA
Pollution degree2
Frequency50 - 60Hz
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V6kA
Concurrently switching neutral conductorNo
Over voltage category-
Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V6kA
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

419164 | RX3 AUTOM OSIG 2P B 63A 6KA 2M

Main Product Image

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 6 KOM
  • LEGRAND

Technical specifications

Degree of protection (IP)

IP20

Voltage type

AC

Suitable for flush-mounted installation

Width in number of modular spacings

2

Rated voltage

400V

Rated current

63A

Built-in depth

44mm

Release characteristic

B

Ambient temperature during operating

- .. -°C

Number of protected poles

2

Connectable conductor cross section multi-wired

- .. -mm²

Connectable conductor cross section solid-core

- .. -mm²

Rated impulse withstand voltage Uimp

4kV

Number of poles (total)

2

Rated insulation voltage Ui

500V

Current limiting class

3

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V

10kA

Additional equipment possible

Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V

10kA

Pollution degree

2

Frequency

50 .. 60Hz

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V

6kA

Concurrently switching neutral conductor

Over voltage category

-

Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V

6kA

*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.