Aleta.hr

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 4 KOM
  • LEGRAND

Technical specifications

Rated voltage400V
Built-in depth44mm
Voltage typeAC
Release characteristicB
Frequency50 - 60Hz
Rated current13A
Pollution degree2
Over voltage category-
Rated insulation voltage Ui500V
Ambient temperature during operating- - -°C
Additional equipment possibleNo
Concurrently switching neutral conductorNo
Connectable conductor cross section multi-wired- - -mm²
Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V10kA
Current limiting class3
Suitable for flush-mounted installationYes
Width in number of modular spacings3
Number of protected poles3
Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V6kA
Number of poles (total)3
Connectable conductor cross section solid-core- - -mm²
Degree of protection (IP)IP20
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V10kA
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V6kA
Rated impulse withstand voltage Uimp4kV
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

419168 | RX3 AUTOM OSIG 3P B 13A 6KA 3M

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 4 KOM
  • LEGRAND

Technical specifications

Rated voltage

400V

Built-in depth

44mm

Voltage type

AC

Release characteristic

B

Frequency

50 .. 60Hz

Rated current

13A

Pollution degree

2

Over voltage category

-

Rated insulation voltage Ui

500V

Ambient temperature during operating

- .. -°C

Additional equipment possible

Concurrently switching neutral conductor

Connectable conductor cross section multi-wired

- .. -mm²

Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V

10kA

Current limiting class

3

Suitable for flush-mounted installation

Width in number of modular spacings

3

Number of protected poles

3

Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V

6kA

Number of poles (total)

3

Connectable conductor cross section solid-core

- .. -mm²

Degree of protection (IP)

IP20

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V

10kA

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V

6kA

Rated impulse withstand voltage Uimp

4kV

VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.