Aleta.hr

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 4 KOM
  • LEGRAND

Technical specifications

Frequency50 - 60Hz
Rated voltage400V
Over voltage category-
Voltage typeAC
Current limiting class3
Built-in depth44mm
Rated current20A
Rated insulation voltage Ui500V
Release characteristicB
Additional equipment possibleNo
Concurrently switching neutral conductorNo
Suitable for flush-mounted installationYes
Number of protected poles3
Ambient temperature during operating- - -°C
Connectable conductor cross section multi-wired- - -mm²
Connectable conductor cross section solid-core- - -mm²
Width in number of modular spacings3
Degree of protection (IP)IP20
Pollution degree2
Rated impulse withstand voltage Uimp4kV
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V10kA
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V6kA
Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V6kA
Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V10kA
Number of poles (total)3
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

419170 | RX3 AUTOM OSIG 3P B 20A 6KA 3M

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 4 KOM
  • LEGRAND

Technical specifications

Frequency

50 .. 60Hz

Rated voltage

400V

Over voltage category

-

Voltage type

AC

Current limiting class

3

Built-in depth

44mm

Rated current

20A

Rated insulation voltage Ui

500V

Release characteristic

B

Additional equipment possible

Concurrently switching neutral conductor

Suitable for flush-mounted installation

Number of protected poles

3

Ambient temperature during operating

- .. -°C

Connectable conductor cross section multi-wired

- .. -mm²

Connectable conductor cross section solid-core

- .. -mm²

Width in number of modular spacings

3

Degree of protection (IP)

IP20

Pollution degree

2

Rated impulse withstand voltage Uimp

4kV

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V

10kA

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V

6kA

Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V

6kA

Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V

10kA

Number of poles (total)

3

VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.