Aleta.hr

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 4 KOM
  • LEGRAND

Technical specifications

Ambient temperature during operating- - -°C
Rated insulation voltage Ui500V
Rated voltage400V
Number of poles (total)3
Width in number of modular spacings3
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V10kA
Degree of protection (IP)IP20
Release characteristicB
Concurrently switching neutral conductorNo
Connectable conductor cross section multi-wired- - -mm²
Built-in depth44mm
Additional equipment possibleNo
Rated impulse withstand voltage Uimp4kV
Pollution degree2
Over voltage category-
Current limiting class3
Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V10kA
Number of protected poles3
Frequency50 - 60Hz
Voltage typeAC
Rated current40A
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V6kA
Connectable conductor cross section solid-core- - -mm²
Suitable for flush-mounted installationYes
Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V6kA
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

419173 | RX3 AUTOM OSIG 3P B 40A 6KA 3M

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 4 KOM
  • LEGRAND

Technical specifications

Ambient temperature during operating

- .. -°C

Rated insulation voltage Ui

500V

Rated voltage

400V

Number of poles (total)

3

Width in number of modular spacings

3

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V

10kA

Degree of protection (IP)

IP20

Release characteristic

B

Concurrently switching neutral conductor

Connectable conductor cross section multi-wired

- .. -mm²

Built-in depth

44mm

Additional equipment possible

Rated impulse withstand voltage Uimp

4kV

Pollution degree

2

Over voltage category

-

Current limiting class

3

Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V

10kA

Number of protected poles

3

Frequency

50 .. 60Hz

Voltage type

AC

Rated current

40A

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V

6kA

Connectable conductor cross section solid-core

- .. -mm²

Suitable for flush-mounted installation

Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V

6kA

VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.