Aleta.hr

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 12 KOM
  • LEGRAND

Technical specifications

Built-in depth44mm
Frequency50 - 60Hz
Rated insulation voltage Ui500V
Release characteristicC
Current limiting class3
Connectable conductor cross section solid-core- - -mm²
Additional equipment possibleNo
Suitable for flush-mounted installationYes
Width in number of modular spacings1
Connectable conductor cross section multi-wired- - -mm²
Number of protected poles1
Over voltage category-
Rated current10A
Voltage typeAC
Degree of protection (IP)IP20
Rated voltage230V
Number of poles (total)1
Pollution degree2
Ambient temperature during operating- - -°C
Concurrently switching neutral conductorNo
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V6kA
Rated impulse withstand voltage Uimp4kV
Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V-kA
Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V6kA
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V-kA
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

419200 | RX3 AUTOM OSIG 1P C 10A 6KA 1M

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 12 KOM
  • LEGRAND

Technical specifications

Built-in depth

44mm

Frequency

50 .. 60Hz

Rated insulation voltage Ui

500V

Release characteristic

C

Current limiting class

3

Connectable conductor cross section solid-core

- .. -mm²

Additional equipment possible

Suitable for flush-mounted installation

Width in number of modular spacings

1

Connectable conductor cross section multi-wired

- .. -mm²

Number of protected poles

1

Over voltage category

-

Rated current

10A

Voltage type

AC

Degree of protection (IP)

IP20

Rated voltage

230V

Number of poles (total)

1

Pollution degree

2

Ambient temperature during operating

- .. -°C

Concurrently switching neutral conductor

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V

6kA

Rated impulse withstand voltage Uimp

4kV

Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V

-kA

Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V

6kA

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V

-kA

VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.