Aleta.hr

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 12 KOM
  • LEGRAND

Technical specifications

Rated insulation voltage Ui500V
Current limiting class3
Release characteristicC
Width in number of modular spacings1
Pollution degree2
Rated voltage230V
Frequency50 - 60Hz
Built-in depth44mm
Over voltage category-
Voltage typeAC
Rated current13A
Connectable conductor cross section multi-wired- - -mm²
Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V-kA
Number of poles (total)1
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V6kA
Additional equipment possibleNo
Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V6kA
Suitable for flush-mounted installationYes
Degree of protection (IP)IP20
Ambient temperature during operating- - -°C
Rated impulse withstand voltage Uimp4kV
Connectable conductor cross section solid-core- - -mm²
Concurrently switching neutral conductorNo
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V-kA
Number of protected poles1
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

419201 | RX3 AUTOM OSIG 1P C 13A 6KA 1M

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 12 KOM
  • LEGRAND

Technical specifications

Rated insulation voltage Ui

500V

Current limiting class

3

Release characteristic

C

Width in number of modular spacings

1

Pollution degree

2

Rated voltage

230V

Frequency

50 .. 60Hz

Built-in depth

44mm

Over voltage category

-

Voltage type

AC

Rated current

13A

Connectable conductor cross section multi-wired

- .. -mm²

Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V

-kA

Number of poles (total)

1

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V

6kA

Additional equipment possible

Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V

6kA

Suitable for flush-mounted installation

Degree of protection (IP)

IP20

Ambient temperature during operating

- .. -°C

Rated impulse withstand voltage Uimp

4kV

Connectable conductor cross section solid-core

- .. -mm²

Concurrently switching neutral conductor

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V

-kA

Number of protected poles

1

VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.