Technical specifications

Pollution degree2
Built-in depth44mm
Release characteristicC
Degree of protection (IP)IP20
Rated voltage400V
Number of protected poles2
Rated current6A
Voltage typeAC
Frequency50 - 60Hz
Current limiting class3
Rated insulation voltage Ui500V
Width in number of modular spacings2
Over voltage category-
Concurrently switching neutral conductorNo
Suitable for flush-mounted installationYes
Connectable conductor cross section multi-wired- - -mm²
Additional equipment possibleNo
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V6kA
Number of poles (total)2
Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V10kA
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V10kA
Rated impulse withstand voltage Uimp4kV
Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V6kA
Connectable conductor cross section solid-core- - -mm²
Ambient temperature during operating- - -°C
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

419221 | RX3 AUTOM OSIG 2P C 6A 6KA 2M

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 6 KOM
  • LEGRAND

Technical specifications

Pollution degree

2

Built-in depth

44mm

Release characteristic

C

Degree of protection (IP)

IP20

Rated voltage

400V

Number of protected poles

2

Rated current

6A

Voltage type

AC

Frequency

50 .. 60Hz

Current limiting class

3

Rated insulation voltage Ui

500V

Width in number of modular spacings

2

Over voltage category

-

Concurrently switching neutral conductor

Suitable for flush-mounted installation

Connectable conductor cross section multi-wired

- .. -mm²

Additional equipment possible

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V

6kA

Number of poles (total)

2

Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V

10kA

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V

10kA

Rated impulse withstand voltage Uimp

4kV

Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V

6kA

Connectable conductor cross section solid-core

- .. -mm²

Ambient temperature during operating

- .. -°C