Aleta.hr

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 4 KOM
  • LEGRAND

Technical specifications

Width in number of modular spacings3
Rated voltage400V
Voltage typeAC
Rated current50A
Built-in depth44mm
Over voltage category-
Connectable conductor cross section multi-wired- - -mm²
Frequency50 - 60Hz
Degree of protection (IP)IP20
Pollution degree2
Current limiting class3
Connectable conductor cross section solid-core- - -mm²
Release characteristicC
Rated insulation voltage Ui500V
Ambient temperature during operating- - -°C
Concurrently switching neutral conductorNo
Number of protected poles3
Suitable for flush-mounted installationYes
Additional equipment possibleNo
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V6kA
Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V10kA
Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V6kA
Number of poles (total)3
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V10kA
Rated impulse withstand voltage Uimp4kV
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

419240 | RX3 AUTOM OSIG 3P C 50A 6KA 3M

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 4 KOM
  • LEGRAND

Technical specifications

Width in number of modular spacings

3

Rated voltage

400V

Voltage type

AC

Rated current

50A

Built-in depth

44mm

Over voltage category

-

Connectable conductor cross section multi-wired

- .. -mm²

Frequency

50 .. 60Hz

Degree of protection (IP)

IP20

Pollution degree

2

Current limiting class

3

Connectable conductor cross section solid-core

- .. -mm²

Release characteristic

C

Rated insulation voltage Ui

500V

Ambient temperature during operating

- .. -°C

Concurrently switching neutral conductor

Number of protected poles

3

Suitable for flush-mounted installation

Additional equipment possible

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V

6kA

Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V

10kA

Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V

6kA

Number of poles (total)

3

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V

10kA

Rated impulse withstand voltage Uimp

4kV

VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.