Number of auxiliary contacts as normally open contact-
Number of auxiliary contacts as normally closed contact1
Rated permanent current Iu40A
Number of poles3
With switched-off indicatorYes
Rated voltage220 - 690V
Motor drive integratedNo
Degree of protection (IP)IP30
Integrated earth fault protectionNo
Overload release current setting32 - 40A
With under voltage releaseYes
Position of connection for main current circuitFront side
Adjustment range short-term delayed short-circuit release400 - 400A
Type of electrical connection of main circuitScrew connection
Number of auxiliary contacts as change-over contact1
Motor drive optionalYes
Adjustment range undelayed short-circuit release400 - 400A
Suitable for DIN rail (top hat rail) mountingYes
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz16kA
DIN rail (top hat rail) mounting optionalYes
Device constructionBuilt-in device fixed built-in technique
Type of control elementToggle
Complete device with protection unitYes
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

420002 | DPX3 160-TM 3P 40A 16KA

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Low-voltage industrial components
  • Power circuit-breaker for trafo/generator/installation protection
  • 1 KOM
  • LEGRAND

Technical specifications

Number of auxiliary contacts as normally open contact

-

Number of auxiliary contacts as normally closed contact

1

Rated permanent current Iu

40A

Number of poles

3

With switched-off indicator

Rated voltage

220 .. 690V

Motor drive integrated

Degree of protection (IP)

IP30

Integrated earth fault protection

Overload release current setting

32 .. 40A

With under voltage release

Position of connection for main current circuit

Front side

Adjustment range short-term delayed short-circuit release

400 .. 400A

Type of electrical connection of main circuit

Screw connection

Number of auxiliary contacts as change-over contact

1

Motor drive optional

Adjustment range undelayed short-circuit release

400 .. 400A

Suitable for DIN rail (top hat rail) mounting

Rated short-circuit breaking capacity lcu at 400 V, 50 Hz

16kA

DIN rail (top hat rail) mounting optional

Device construction

Built-in device fixed built-in technique

Type of control element

Toggle

Complete device with protection unit