Aleta.hr

Details

  • Low-voltage industrial components
  • Power circuit-breaker for trafo/generator/installation protection
  • 1 KOM
  • LEGRAND

Technical specifications

Degree of protection (IP)IP30
Type of control elementToggle
Number of poles3
Number of auxiliary contacts as normally open contact-
Rated permanent current Iu225A
Number of auxiliary contacts as normally closed contact1
Motor drive integratedNo
Overload release current setting225 - 225A
Device constructionBuilt-in device fixed built-in technique
Rated voltage110 - 550V
Type of electrical connection of main circuitScrew connection
Motor drive optionalNo
Number of auxiliary contacts as change-over contact1
Suitable for DIN rail (top hat rail) mountingYes
Adjustment range undelayed short-circuit release2250 - 2250A
With under voltage releaseYes
With switched-off indicatorYes
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz18kA
Adjustment range short-term delayed short-circuit release2250 - 2250A
Position of connection for main current circuitFront side
Complete device with protection unitYes
DIN rail (top hat rail) mounting optionalYes
Integrated earth fault protectionNo
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

427104 | DRX250 STRUJNI PR 3P 225A 18KA

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Low-voltage industrial components
  • Power circuit-breaker for trafo/generator/installation protection
  • 1 KOM
  • LEGRAND

Technical specifications

Degree of protection (IP)

IP30

Type of control element

Toggle

Number of poles

3

Number of auxiliary contacts as normally open contact

-

Rated permanent current Iu

225A

Number of auxiliary contacts as normally closed contact

1

Motor drive integrated

Overload release current setting

225 .. 225A

Device construction

Built-in device fixed built-in technique

Rated voltage

110 .. 550V

Type of electrical connection of main circuit

Screw connection

Motor drive optional

Number of auxiliary contacts as change-over contact

1

Suitable for DIN rail (top hat rail) mounting

Adjustment range undelayed short-circuit release

2250 .. 2250A

With under voltage release

With switched-off indicator

Rated short-circuit breaking capacity lcu at 400 V, 50 Hz

18kA

Adjustment range short-term delayed short-circuit release

2250 .. 2250A

Position of connection for main current circuit

Front side

Complete device with protection unit

DIN rail (top hat rail) mounting optional

Integrated earth fault protection

VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.