  • Low-voltage industrial components
  • Power circuit-breaker for trafo/generator/installation protection
  • 1 KOM
  • LEGRAND

Technical specifications

Rated permanent current Iu250A
Number of auxiliary contacts as normally open contact-
Number of auxiliary contacts as normally closed contact1
Overload release current setting250 - 250A
Position of connection for main current circuitFront side
Rated voltage110 - 550V
Degree of protection (IP)IP30
Number of auxiliary contacts as change-over contact1
Number of poles3
Adjustment range short-term delayed short-circuit release2500 - 2500A
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz18kA
With switched-off indicatorYes
Type of electrical connection of main circuitScrew connection
Motor drive integratedNo
Type of control elementToggle
Adjustment range undelayed short-circuit release2500 - 2500A
Suitable for DIN rail (top hat rail) mountingYes
With under voltage releaseYes
Motor drive optionalNo
Complete device with protection unitYes
DIN rail (top hat rail) mounting optionalYes
Integrated earth fault protectionNo
Device constructionBuilt-in device fixed built-in technique
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

Item is no longer available for sale!

427105 | DRX 250B 3P 250A

Main Product Image

Details

  • Low-voltage industrial components
  • Power circuit-breaker for trafo/generator/installation protection
  • 1 KOM
  • LEGRAND

Technical specifications

Rated permanent current Iu

250A

Number of auxiliary contacts as normally open contact

-

Number of auxiliary contacts as normally closed contact

1

Overload release current setting

250 .. 250A

Position of connection for main current circuit

Front side

Rated voltage

110 .. 550V

Degree of protection (IP)

IP30

Number of auxiliary contacts as change-over contact

1

Number of poles

3

Adjustment range short-term delayed short-circuit release

2500 .. 2500A

Rated short-circuit breaking capacity lcu at 400 V, 50 Hz

18kA

With switched-off indicator

Type of electrical connection of main circuit

Screw connection

Motor drive integrated

Type of control element

Toggle

Adjustment range undelayed short-circuit release

2500 .. 2500A

Suitable for DIN rail (top hat rail) mounting

With under voltage release

Motor drive optional

Complete device with protection unit

DIN rail (top hat rail) mounting optional

Integrated earth fault protection

Device construction