Aleta.hr

Details

  • Low-voltage industrial components
  • Power circuit-breaker for trafo/generator/installation protection
  • 1 KOM
  • LEGRAND

Technical specifications

Degree of protection (IP)IP30
Type of control elementToggle
Number of poles3
Number of auxiliary contacts as normally open contact-
Rated permanent current Iu125A
Number of auxiliary contacts as normally closed contact1
Motor drive integratedNo
Overload release current setting125 - 125A
Rated voltage110 - 550V
Type of electrical connection of main circuitScrew connection
Motor drive optionalNo
Number of auxiliary contacts as change-over contact1
Device constructionBuilt-in device fixed built-in technique
Suitable for DIN rail (top hat rail) mountingYes
Adjustment range undelayed short-circuit release1250 - 1250A
With under voltage releaseYes
With switched-off indicatorYes
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz25kA
Adjustment range short-term delayed short-circuit release1250 - 1250A
Position of connection for main current circuitFront side
Complete device with protection unitYes
DIN rail (top hat rail) mounting optionalYes
Integrated earth fault protectionNo
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

427112 | DRX250 STRUJNI PR 3P 125A 25KA

Main Product Image

Details

  • Low-voltage industrial components
  • Power circuit-breaker for trafo/generator/installation protection
  • 1 KOM
  • LEGRAND

Technical specifications

Degree of protection (IP)

IP30

Type of control element

Toggle

Number of poles

3

Number of auxiliary contacts as normally open contact

-

Rated permanent current Iu

125A

Number of auxiliary contacts as normally closed contact

1

Motor drive integrated

Overload release current setting

125 .. 125A

Rated voltage

110 .. 550V

Type of electrical connection of main circuit

Screw connection

Motor drive optional

Number of auxiliary contacts as change-over contact

1

Device construction

Built-in device fixed built-in technique

Suitable for DIN rail (top hat rail) mounting

Adjustment range undelayed short-circuit release

1250 .. 1250A

With under voltage release

With switched-off indicator

Rated short-circuit breaking capacity lcu at 400 V, 50 Hz

25kA

Adjustment range short-term delayed short-circuit release

1250 .. 1250A

Position of connection for main current circuit

Front side

Complete device with protection unit

DIN rail (top hat rail) mounting optional

Integrated earth fault protection

*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.