Aleta.hr

Details

  • Low-voltage industrial components
  • Power circuit-breaker for trafo/generator/installation protection
  • 1 KOM
  • LEGRAND

Technical specifications

Overload release current setting125 - 125A
Number of poles3
Number of auxiliary contacts as normally open contact-
Rated permanent current Iu125A
Number of auxiliary contacts as normally closed contact1
Rated voltage110 - 550V
Degree of protection (IP)IP30
With switched-off indicatorYes
Number of auxiliary contacts as change-over contact1
Type of control elementToggle
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz25kA
Type of electrical connection of main circuitScrew connection
Position of connection for main current circuitFront side
Motor drive integratedNo
Adjustment range undelayed short-circuit release1250 - 1250A
Adjustment range short-term delayed short-circuit release1250 - 1250A
Suitable for DIN rail (top hat rail) mountingYes
Integrated earth fault protectionNo
With under voltage releaseYes
Motor drive optionalNo
DIN rail (top hat rail) mounting optionalYes
Complete device with protection unitYes
Device constructionBuilt-in device fixed built-in technique
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

Item is no longer available for sale!

427112 | DRX250 STRUJNI PR 3P 125A 25KA

Main Product Image

Details

  • Low-voltage industrial components
  • Power circuit-breaker for trafo/generator/installation protection
  • 1 KOM
  • LEGRAND

Technical specifications

Overload release current setting

125 .. 125A

Number of poles

3

Number of auxiliary contacts as normally open contact

-

Rated permanent current Iu

125A

Number of auxiliary contacts as normally closed contact

1

Rated voltage

110 .. 550V

Degree of protection (IP)

IP30

With switched-off indicator

Number of auxiliary contacts as change-over contact

1

Type of control element

Toggle

Rated short-circuit breaking capacity lcu at 400 V, 50 Hz

25kA

Type of electrical connection of main circuit

Screw connection

Position of connection for main current circuit

Front side

Motor drive integrated

Adjustment range undelayed short-circuit release

1250 .. 1250A

Adjustment range short-term delayed short-circuit release

1250 .. 1250A

Suitable for DIN rail (top hat rail) mounting

Integrated earth fault protection

With under voltage release

Motor drive optional

DIN rail (top hat rail) mounting optional

Complete device with protection unit

Device construction

Built-in device fixed built-in technique

VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.