  • Low-voltage industrial components
  • Power circuit-breaker for trafo/generator/installation protection
  • 1 KOM
  • LEGRAND

Technical specifications

Number of auxiliary contacts as normally open contact-
Number of auxiliary contacts as normally closed contact1
Number of poles3
Number of auxiliary contacts as change-over contact1
Rated permanent current Iu200A
Overload release current setting200 - 200A
Degree of protection (IP)IP30
Type of control elementToggle
Type of electrical connection of main circuitScrew connection
Position of connection for main current circuitFront side
Rated voltage110 - 550V
Motor drive integratedNo
With switched-off indicatorYes
Suitable for DIN rail (top hat rail) mountingYes
Adjustment range short-term delayed short-circuit release2000 - 2000A
DIN rail (top hat rail) mounting optionalYes
Integrated earth fault protectionNo
Motor drive optionalNo
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz25kA
Complete device with protection unitYes
Adjustment range undelayed short-circuit release2000 - 2000A
With under voltage releaseYes
Device constructionBuilt-in device fixed built-in technique
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

Item is no longer available for sale!

427115 | DRX250 STRUJNI PR 3P 200A 25KA

Main Product Image

Details

  • Low-voltage industrial components
  • Power circuit-breaker for trafo/generator/installation protection
  • 1 KOM
  • LEGRAND

Technical specifications

Number of auxiliary contacts as normally open contact

-

Number of auxiliary contacts as normally closed contact

1

Number of poles

3

Number of auxiliary contacts as change-over contact

1

Rated permanent current Iu

200A

Overload release current setting

200 .. 200A

Degree of protection (IP)

IP30

Type of control element

Toggle

Type of electrical connection of main circuit

Screw connection

Position of connection for main current circuit

Front side

Rated voltage

110 .. 550V

Motor drive integrated

With switched-off indicator

Suitable for DIN rail (top hat rail) mounting

Adjustment range short-term delayed short-circuit release

2000 .. 2000A

DIN rail (top hat rail) mounting optional

Integrated earth fault protection

Motor drive optional

Rated short-circuit breaking capacity lcu at 400 V, 50 Hz

25kA

Complete device with protection unit

Adjustment range undelayed short-circuit release

2000 .. 2000A

With under voltage release

Device construction

Built-in device fixed built-in technique