Technical specifications

Number of auxiliary contacts as normally open contact-
Overload release current setting200 - 200A
Rated permanent current Iu200A
Number of auxiliary contacts as change-over contact1
Rated voltage110 - 550V
Number of auxiliary contacts as normally closed contact1
Number of poles3
Type of electrical connection of main circuitScrew connection
Type of control elementToggle
Position of connection for main current circuitFront side
Degree of protection (IP)IP30
Motor drive integratedNo
Suitable for DIN rail (top hat rail) mountingYes
With switched-off indicatorYes
Adjustment range undelayed short-circuit release2000 - 2000A
Integrated earth fault protectionNo
Motor drive optionalNo
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz36kA
Adjustment range short-term delayed short-circuit release2000 - 2000A
With under voltage releaseYes
Complete device with protection unitYes
DIN rail (top hat rail) mounting optionalYes
Device constructionBuilt-in device fixed built-in technique
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

Item is no longer available for sale!

427127 | DRX250 STRUJNI PR 3P 200A 36KA

Main Product Image

Details

  • Low-voltage industrial components
  • Power circuit-breaker for trafo/generator/installation protection
  • 1 KOM
  • LEGRAND

Technical specifications

Number of auxiliary contacts as normally open contact

-

Overload release current setting

200 .. 200A

Rated permanent current Iu

200A

Number of auxiliary contacts as change-over contact

1

Rated voltage

110 .. 550V

Number of auxiliary contacts as normally closed contact

1

Number of poles

3

Type of electrical connection of main circuit

Screw connection

Type of control element

Toggle

Position of connection for main current circuit

Front side

Degree of protection (IP)

IP30

Motor drive integrated

Suitable for DIN rail (top hat rail) mounting

With switched-off indicator

Adjustment range undelayed short-circuit release

2000 .. 2000A

Integrated earth fault protection

Motor drive optional

Rated short-circuit breaking capacity lcu at 400 V, 50 Hz

36kA

Adjustment range short-term delayed short-circuit release

2000 .. 2000A

With under voltage release

Complete device with protection unit

DIN rail (top hat rail) mounting optional

Device construction

Built-in device fixed built-in technique

VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.