Aleta.hr

Details

  • Low-voltage industrial components
  • Power circuit-breaker for trafo/generator/installation protection
  • 1 KOM
  • LEGRAND

Technical specifications

Rated permanent current Iu250A
Number of auxiliary contacts as normally closed contact1
Number of auxiliary contacts as normally open contact-
Degree of protection (IP)IP30
Overload release current setting250 - 250A
Type of electrical connection of main circuitScrew connection
Rated voltage110 - 550V
Number of poles3
Number of auxiliary contacts as change-over contact1
Motor drive integratedNo
Position of connection for main current circuitFront side
Suitable for DIN rail (top hat rail) mountingYes
Adjustment range short-term delayed short-circuit release2500 - 2500A
Integrated earth fault protectionNo
With under voltage releaseYes
With switched-off indicatorYes
Adjustment range undelayed short-circuit release2500 - 2500A
Motor drive optionalNo
Device constructionBuilt-in device fixed built-in technique
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz36kA
Complete device with protection unitYes
DIN rail (top hat rail) mounting optionalYes
Type of control elementToggle
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

Item is no longer available for sale!

427129 | DRX250 STRUJNI PR 3P 250A 36KA

Main Product Image

Details

  • Low-voltage industrial components
  • Power circuit-breaker for trafo/generator/installation protection
  • 1 KOM
  • LEGRAND

Technical specifications

Rated permanent current Iu

250A

Number of auxiliary contacts as normally closed contact

1

Number of auxiliary contacts as normally open contact

-

Degree of protection (IP)

IP30

Overload release current setting

250 .. 250A

Type of electrical connection of main circuit

Screw connection

Rated voltage

110 .. 550V

Number of poles

3

Number of auxiliary contacts as change-over contact

1

Motor drive integrated

Position of connection for main current circuit

Front side

Suitable for DIN rail (top hat rail) mounting

Adjustment range short-term delayed short-circuit release

2500 .. 2500A

Integrated earth fault protection

With under voltage release

With switched-off indicator

Adjustment range undelayed short-circuit release

2500 .. 2500A

Motor drive optional

Device construction

Built-in device fixed built-in technique

Rated short-circuit breaking capacity lcu at 400 V, 50 Hz

36kA

Complete device with protection unit

DIN rail (top hat rail) mounting optional

Type of control element

Toggle

VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.