Aleta.hr

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 10 KOM
  • LEGRAND

Technical specifications

Built-in depth44mm
Over voltage category-
Rated voltage230V
Pollution degree2
Degree of protection (IP)IP20
Suitable for flush-mounted installationYes
Connectable conductor cross section solid-core- - -mm²
Width in number of modular spacings1
Voltage typeAC
Number of protected poles1
Concurrently switching neutral conductorNo
Rated insulation voltage Ui500V
Current limiting class3
Additional equipment possibleYes
Ambient temperature during operating- - -°C
Frequency50 - 60Hz
Connectable conductor cross section multi-wired- - -mm²
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V-kA
Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V-kA
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V-kA
Rated impulse withstand voltage Uimp4kV
Rated current13A
Release characteristicB
Number of poles (total)1
Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V6kA
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

403356 | TX3 AUT Osig 1P B13 6000A

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 10 KOM
  • LEGRAND

Technical specifications

Built-in depth

44mm

Over voltage category

-

Rated voltage

230V

Pollution degree

2

Degree of protection (IP)

IP20

Suitable for flush-mounted installation

Connectable conductor cross section solid-core

- .. -mm²

Width in number of modular spacings

1

Voltage type

AC

Number of protected poles

1

Concurrently switching neutral conductor

Rated insulation voltage Ui

500V

Current limiting class

3

Additional equipment possible

Ambient temperature during operating

- .. -°C

Frequency

50 .. 60Hz

Connectable conductor cross section multi-wired

- .. -mm²

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V

-kA

Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V

-kA

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V

-kA

Rated impulse withstand voltage Uimp

4kV

Rated current

13A

Release characteristic

B

Number of poles (total)

1

Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V

6kA

VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.