Aleta.hr

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 10 KOM
  • LEGRAND

Technical specifications

Built-in depth44mm
Voltage typeAC
Pollution degree2
Frequency50 - 60Hz
Release characteristicB
Concurrently switching neutral conductorNo
Width in number of modular spacings1
Rated insulation voltage Ui500V
Number of protected poles1
Current limiting class3
Over voltage category-
Degree of protection (IP)IP20
Rated current25A
Rated voltage230V
Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V-kA
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V-kA
Suitable for flush-mounted installationYes
Additional equipment possibleYes
Connectable conductor cross section multi-wired- - -mm²
Number of poles (total)1
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V-kA
Ambient temperature during operating- - -°C
Connectable conductor cross section solid-core- - -mm²
Rated impulse withstand voltage Uimp4kV
Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V6kA
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

403359 | TX3 AUT OSIG.1P.B25 6000A

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 10 KOM
  • LEGRAND

Technical specifications

Built-in depth

44mm

Voltage type

AC

Pollution degree

2

Frequency

50 .. 60Hz

Release characteristic

B

Concurrently switching neutral conductor

Width in number of modular spacings

1

Rated insulation voltage Ui

500V

Number of protected poles

1

Current limiting class

3

Over voltage category

-

Degree of protection (IP)

IP20

Rated current

25A

Rated voltage

230V

Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V

-kA

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V

-kA

Suitable for flush-mounted installation

Additional equipment possible

Connectable conductor cross section multi-wired

- .. -mm²

Number of poles (total)

1

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V

-kA

Ambient temperature during operating

- .. -°C

Connectable conductor cross section solid-core

- .. -mm²

Rated impulse withstand voltage Uimp

4kV

Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V

6kA

VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.