Aleta.hr

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 10 KOM
  • LEGRAND

Technical specifications

Built-in depth44mm
Pollution degree2
Rated voltage230V
Current limiting class3
Width in number of modular spacings1
Degree of protection (IP)IP20
Number of protected poles1
Rated current50A
Voltage typeAC
Rated insulation voltage Ui500V
Connectable conductor cross section multi-wired- - -mm²
Concurrently switching neutral conductorNo
Over voltage category-
Additional equipment possibleYes
Ambient temperature during operating- - -°C
Frequency50 - 60Hz
Release characteristicB
Connectable conductor cross section solid-core- - -mm²
Suitable for flush-mounted installationYes
Number of poles (total)1
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V-kA
Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V6kA
Rated impulse withstand voltage Uimp4kV
Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V-kA
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V-kA
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

403362 | TX3 AUT OSIG. 1P.B50 6000A

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 10 KOM
  • LEGRAND

Technical specifications

Built-in depth

44mm

Pollution degree

2

Rated voltage

230V

Current limiting class

3

Width in number of modular spacings

1

Degree of protection (IP)

IP20

Number of protected poles

1

Rated current

50A

Voltage type

AC

Rated insulation voltage Ui

500V

Connectable conductor cross section multi-wired

- .. -mm²

Concurrently switching neutral conductor

Over voltage category

-

Additional equipment possible

Ambient temperature during operating

- .. -°C

Frequency

50 .. 60Hz

Release characteristic

B

Connectable conductor cross section solid-core

- .. -mm²

Suitable for flush-mounted installation

Number of poles (total)

1

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V

-kA

Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V

6kA

Rated impulse withstand voltage Uimp

4kV

Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V

-kA

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V

-kA

VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.