Aleta.hr

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • LEGRAND

Technical specifications

Voltage typeAC
Built-in depth44mm
Rated current25A
Release characteristicB
Current limiting class3
Concurrently switching neutral conductorNo
Suitable for flush-mounted installationYes
Pollution degree2
Number of protected poles3
Rated voltage400V
Degree of protection (IP)IP20
Over voltage category-
Width in number of modular spacings3
Frequency50 - 60Hz
Rated insulation voltage Ui500V
Connectable conductor cross section multi-wired- - -mm²
Number of poles (total)3
Additional equipment possibleYes
Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V6kA
Connectable conductor cross section solid-core- - -mm²
Ambient temperature during operating- - -°C
Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V10kA
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V-kA
Rated impulse withstand voltage Uimp4kV
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V-kA
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

403404 | TX3 AUT OSIG.3P.B25 6000A

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • LEGRAND

Technical specifications

Voltage type

AC

Built-in depth

44mm

Rated current

25A

Release characteristic

B

Current limiting class

3

Concurrently switching neutral conductor

Suitable for flush-mounted installation

Pollution degree

2

Number of protected poles

3

Rated voltage

400V

Degree of protection (IP)

IP20

Over voltage category

-

Width in number of modular spacings

3

Frequency

50 .. 60Hz

Rated insulation voltage Ui

500V

Connectable conductor cross section multi-wired

- .. -mm²

Number of poles (total)

3

Additional equipment possible

Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V

6kA

Connectable conductor cross section solid-core

- .. -mm²

Ambient temperature during operating

- .. -°C

Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V

10kA

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V

-kA

Rated impulse withstand voltage Uimp

4kV

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V

-kA

VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.