Aleta.hr

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • LEGRAND

Technical specifications

Rated voltage400V
Degree of protection (IP)IP20
Built-in depth44mm
Width in number of modular spacings4
Release characteristicB
Current limiting class3
Frequency50 - 60Hz
Over voltage category-
Voltage typeAC
Pollution degree2
Rated insulation voltage Ui500V
Rated current20A
Suitable for flush-mounted installationYes
Connectable conductor cross section multi-wired- - -mm²
Concurrently switching neutral conductorYes
Number of protected poles3
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V-kA
Connectable conductor cross section solid-core- - -mm²
Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V10kA
Ambient temperature during operating- - -°C
Rated impulse withstand voltage Uimp4kV
Number of poles (total)4
Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V6kA
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V-kA
Additional equipment possibleYes
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

403418 | TX3 AUT OSIG 4P B20 6000A

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • LEGRAND

Technical specifications

Rated voltage

400V

Degree of protection (IP)

IP20

Built-in depth

44mm

Width in number of modular spacings

4

Release characteristic

B

Current limiting class

3

Frequency

50 .. 60Hz

Over voltage category

-

Voltage type

AC

Pollution degree

2

Rated insulation voltage Ui

500V

Rated current

20A

Suitable for flush-mounted installation

Connectable conductor cross section multi-wired

- .. -mm²

Concurrently switching neutral conductor

Number of protected poles

3

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V

-kA

Connectable conductor cross section solid-core

- .. -mm²

Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V

10kA

Ambient temperature during operating

- .. -°C

Rated impulse withstand voltage Uimp

4kV

Number of poles (total)

4

Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V

6kA

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V

-kA

Additional equipment possible

VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.