Aleta.hr

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • LEGRAND

Technical specifications

Voltage typeAC
Rated current63A
Connectable conductor cross section solid-core- - -mm²
Concurrently switching neutral conductorYes
Rated insulation voltage Ui500V
Over voltage category-
Width in number of modular spacings4
Built-in depth44mm
Degree of protection (IP)IP20
Number of poles (total)4
Release characteristicB
Connectable conductor cross section multi-wired- - -mm²
Frequency50 - 60Hz
Current limiting class3
Additional equipment possibleYes
Pollution degree2
Number of protected poles3
Suitable for flush-mounted installationYes
Ambient temperature during operating- - -°C
Rated voltage400V
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V-kA
Rated impulse withstand voltage Uimp4kV
Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V6kA
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V-kA
Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V10kA
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

403423 | TX3 AUT OSIG 4P B63 6000A

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • LEGRAND

Technical specifications

Voltage type

AC

Rated current

63A

Connectable conductor cross section solid-core

- .. -mm²

Concurrently switching neutral conductor

Rated insulation voltage Ui

500V

Over voltage category

-

Width in number of modular spacings

4

Built-in depth

44mm

Degree of protection (IP)

IP20

Number of poles (total)

4

Release characteristic

B

Connectable conductor cross section multi-wired

- .. -mm²

Frequency

50 .. 60Hz

Current limiting class

3

Additional equipment possible

Pollution degree

2

Number of protected poles

3

Suitable for flush-mounted installation

Ambient temperature during operating

- .. -°C

Rated voltage

400V

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V

-kA

Rated impulse withstand voltage Uimp

4kV

Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V

6kA

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V

-kA

Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V

10kA

VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.