  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 10 KOM
  • LEGRAND

Technical specifications

Voltage typeAC
Frequency50 - 60Hz
Rated voltage230V
Rated current13A
Built-in depth44mm
Width in number of modular spacings1
Current limiting class3
Degree of protection (IP)IP20
Suitable for flush-mounted installationYes
Rated insulation voltage Ui500V
Release characteristicC
Over voltage category-
Number of protected poles1
Pollution degree2
Concurrently switching neutral conductorNo
Connectable conductor cross section solid-core- - -mm²
Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V-kA
Number of poles (total)1
Ambient temperature during operating- - -°C
Additional equipment possibleYes
Connectable conductor cross section multi-wired- - -mm²
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V-kA
Rated impulse withstand voltage Uimp4kV
Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V6kA
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V-kA
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

403433 | TX3 AUT OSIG 1P C13 6000A

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 10 KOM
  • LEGRAND

Technical specifications

Voltage type

AC

Frequency

50 .. 60Hz

Rated voltage

230V

Rated current

13A

Built-in depth

44mm

Width in number of modular spacings

1

Current limiting class

3

Degree of protection (IP)

IP20

Suitable for flush-mounted installation

Rated insulation voltage Ui

500V

Release characteristic

C

Over voltage category

-

Number of protected poles

1

Pollution degree

2

Concurrently switching neutral conductor

Connectable conductor cross section solid-core

- .. -mm²

Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V

-kA

Number of poles (total)

1

Ambient temperature during operating

- .. -°C

Additional equipment possible

Connectable conductor cross section multi-wired

- .. -mm²

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V

-kA

Rated impulse withstand voltage Uimp

4kV

Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V

6kA

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V

-kA