Aleta.hr

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 5 KOM
  • LEGRAND

Technical specifications

Over voltage category-
Current limiting class3
Pollution degree2
Release characteristicC
Rated voltage400V
Rated current20A
Frequency50 - 60Hz
Rated insulation voltage Ui500V
Built-in depth44mm
Voltage typeAC
Concurrently switching neutral conductorNo
Width in number of modular spacings2
Number of protected poles2
Degree of protection (IP)IP20
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V-kA
Additional equipment possibleYes
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V-kA
Connectable conductor cross section multi-wired- - -mm²
Suitable for flush-mounted installationYes
Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V10kA
Ambient temperature during operating- - -°C
Connectable conductor cross section solid-core- - -mm²
Number of poles (total)2
Rated impulse withstand voltage Uimp4kV
Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V6kA
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

403529 | TX3 AUT OSIG.2P.C20 6000A

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 5 KOM
  • LEGRAND

Technical specifications

Over voltage category

-

Current limiting class

3

Pollution degree

2

Release characteristic

C

Rated voltage

400V

Rated current

20A

Frequency

50 .. 60Hz

Rated insulation voltage Ui

500V

Built-in depth

44mm

Voltage type

AC

Concurrently switching neutral conductor

Width in number of modular spacings

2

Number of protected poles

2

Degree of protection (IP)

IP20

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V

-kA

Additional equipment possible

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V

-kA

Connectable conductor cross section multi-wired

- .. -mm²

Suitable for flush-mounted installation

Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V

10kA

Ambient temperature during operating

- .. -°C

Connectable conductor cross section solid-core

- .. -mm²

Number of poles (total)

2

Rated impulse withstand voltage Uimp

4kV

Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V

6kA

VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.