Aleta.hr

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 5 KOM
  • LEGRAND

Technical specifications

Voltage typeAC
Rated voltage400V
Rated current50A
Built-in depth44mm
Over voltage category-
Connectable conductor cross section multi-wired- - -mm²
Rated insulation voltage Ui500V
Number of poles (total)2
Width in number of modular spacings2
Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V6kA
Degree of protection (IP)IP20
Current limiting class3
Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V10kA
Pollution degree2
Frequency50 - 60Hz
Release characteristicC
Ambient temperature during operating- - -°C
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V-kA
Suitable for flush-mounted installationYes
Concurrently switching neutral conductorNo
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V-kA
Connectable conductor cross section solid-core- - -mm²
Additional equipment possibleYes
Number of protected poles2
Rated impulse withstand voltage Uimp4kV
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

403533 | TX3 AUT OSIG. 2P.C50 6000A

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 5 KOM
  • LEGRAND

Technical specifications

Voltage type

AC

Rated voltage

400V

Rated current

50A

Built-in depth

44mm

Over voltage category

-

Connectable conductor cross section multi-wired

- .. -mm²

Rated insulation voltage Ui

500V

Number of poles (total)

2

Width in number of modular spacings

2

Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V

6kA

Degree of protection (IP)

IP20

Current limiting class

3

Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V

10kA

Pollution degree

2

Frequency

50 .. 60Hz

Release characteristic

C

Ambient temperature during operating

- .. -°C

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V

-kA

Suitable for flush-mounted installation

Concurrently switching neutral conductor

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V

-kA

Connectable conductor cross section solid-core

- .. -mm²

Additional equipment possible

Number of protected poles

2

Rated impulse withstand voltage Uimp

4kV

VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.