Aleta.hr

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • LEGRAND

Technical specifications

Rated voltage400V
Built-in depth44mm
Frequency50 - 60Hz
Voltage typeAC
Rated current32A
Rated insulation voltage Ui500V
Over voltage category-
Width in number of modular spacings3
Release characteristicC
Degree of protection (IP)IP20
Connectable conductor cross section solid-core- - -mm²
Number of protected poles3
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V-kA
Concurrently switching neutral conductorNo
Suitable for flush-mounted installationYes
Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V6kA
Connectable conductor cross section multi-wired- - -mm²
Number of poles (total)3
Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V10kA
Ambient temperature during operating- - -°C
Additional equipment possibleYes
Current limiting class3
Pollution degree2
Rated impulse withstand voltage Uimp4kV
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V-kA
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

403548 | TX3 AUT OSIG. 3P.C32 6000A

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • LEGRAND

Technical specifications

Rated voltage

400V

Built-in depth

44mm

Frequency

50 .. 60Hz

Voltage type

AC

Rated current

32A

Rated insulation voltage Ui

500V

Over voltage category

-

Width in number of modular spacings

3

Release characteristic

C

Degree of protection (IP)

IP20

Connectable conductor cross section solid-core

- .. -mm²

Number of protected poles

3

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V

-kA

Concurrently switching neutral conductor

Suitable for flush-mounted installation

Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V

6kA

Connectable conductor cross section multi-wired

- .. -mm²

Number of poles (total)

3

Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V

10kA

Ambient temperature during operating

- .. -°C

Additional equipment possible

Current limiting class

3

Pollution degree

2

Rated impulse withstand voltage Uimp

4kV

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V

-kA

VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.