Technical specifications

Degree of protection (IP)IP40
Number of poles3
Type of control elementToggle
Number of auxiliary contacts as normally open contact0
Rated permanent current Iu630A
Number of auxiliary contacts as normally closed contact0
Overload release current setting250 - 630A
Motor drive optionalYes
Motor drive integratedNo
Rated voltage690 - 690V
Type of electrical connection of main circuitScrew connection
Number of auxiliary contacts as change-over contact0
Device constructionBuilt-in device fixed built-in technique
Adjustment range undelayed short-circuit release945 - 6930A
Suitable for DIN rail (top hat rail) mountingNo
With under voltage releaseNo
With switched-off indicatorYes
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz100kA
Adjustment range short-term delayed short-circuit release375 - 6300A
Position of connection for main current circuitFront side
Complete device with protection unitYes
DIN rail (top hat rail) mounting optionalNo
Integrated earth fault protectionNo
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

LV433744

Main Product Image

Details

  • Low-voltage industrial components
  • Power circuit-breaker for trafo/generator/installation protection
  • 1 KOM
  • SCHNEIDER

Technical specifications

Degree of protection (IP)

IP40

Number of poles

3

Type of control element

Toggle

Number of auxiliary contacts as normally open contact

0

Rated permanent current Iu

630A

Number of auxiliary contacts as normally closed contact

0

Overload release current setting

250 .. 630A

Motor drive optional

Motor drive integrated

Rated voltage

690 .. 690V

Type of electrical connection of main circuit

Screw connection

Number of auxiliary contacts as change-over contact

0

Device construction

Built-in device fixed built-in technique

Adjustment range undelayed short-circuit release

945 .. 6930A

Suitable for DIN rail (top hat rail) mounting

With under voltage release

With switched-off indicator

Rated short-circuit breaking capacity lcu at 400 V, 50 Hz

100kA

Adjustment range short-term delayed short-circuit release

375 .. 6300A

Position of connection for main current circuit

Front side

Complete device with protection unit

DIN rail (top hat rail) mounting optional

Integrated earth fault protection