Supply voltage AC 50 Hz- - -V
Supply voltage AC 60 Hz- - -V
Supply voltage DC19.2 - 28.8V
Number of relay outputs0
Voltage type of supply voltageDC
Max. number of time switches255
Processing time (1K, binary operation)0.2ms
ModelCompact
Number of interfaces PROFINET0
Number of HW-interfaces RS-2321
Number of HW-interfaces industrial Ethernet1
Number of HW-interfaces RS-4220
Number of HW-interfaces USB1
Number of HW-interfaces RS-4851
With optical interfaceNo
Number of HW-interfaces other0
Number of HW-interfaces Wireless0
Number of analogue outputs0
Number of digital outputs16
Number of HW-interfaces parallel0
Number of analogue inputs2
Number of digital inputs24
Supporting protocol for PROFIBUSNo
Supporting protocol for TCP/IPYes
Supporting protocol for INTERBUSNo
Supporting protocol for SUCONETNo
Supporting protocol for ASINo
Supporting protocol for KNXNo
Supporting protocol for ModbusYes
Supporting protocol for DeviceNetNo
Supporting protocol for PROFINET CBANo
Supporting protocol for SERCOSNo
Supporting protocol for LONNo
Supporting protocol for EtherNet/IPNo
Supporting protocol for Foundation FieldbusNo
Supporting protocol for CANNo
Supporting protocol for Data-HighwayNo
Supporting protocol for PROFINET IONo
Long-Term Evolution (LTE)No
Supporting protocol for AS-Interface Safety at WorkNo
System accessoryNo
RedundancyNo
With displayNo
Type of memoryRAM
Memory size512kByte
Additional program memory possibleYes
Rail mounting possibleYes
Wall mounting/direct mountingYes
Suitable for safety functionsNo
Rack-assembly possibleNo
Front built-in possibleNo
SIL according to IEC 61508None
IO link masterNo
Performance level according to EN ISO 13849-1None
Appendant operation agent (Ex ia)No
Explosion safety category for gasNone
Appendant operation agent (Ex ib)No
Explosion safety category for dustNone
Width163mm
Depth75.9mm
Height103.6mm
Supporting protocol for DeviceNet SafetyNo
Supporting protocol for PROFIsafeNo
Supporting protocol for INTERBUS-SafetyNo
Supporting protocol for SafetyBUS pNo
Supporting protocol for other bus systemsNo
Supporting protocol for DNP3No
Supporting protocol for IEC 60870No
Supporting protocol for IEC 61850 EthernetNo
Radio standard BluetoothNo
Radio standard GSMNo
Radio standard UMTSNo
Radio standard GPRSNo
Radio standard Wi-Fi 802.11No
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

TM221CE40U

Main Product Image

Details

  • Programmable logic controllers PLC
  • PLC CPU-module
  • 1 KOM
  • SCHNEIDER

Technical specifications

Supply voltage AC 50 Hz

- .. -V

Supply voltage AC 60 Hz

- .. -V

Supply voltage DC

19.2 .. 28.8V

Number of relay outputs

0

Voltage type of supply voltage

DC

Max. number of time switches

255

Processing time (1K, binary operation)

0.2ms

Model

Compact

Number of interfaces PROFINET

0

Number of HW-interfaces RS-232

1

Number of HW-interfaces industrial Ethernet

1

Number of HW-interfaces RS-422

0

Number of HW-interfaces USB

1

Number of HW-interfaces RS-485

1

With optical interface

Number of HW-interfaces other

0

Number of HW-interfaces Wireless

0

Number of analogue outputs

0

Number of digital outputs

16

Number of HW-interfaces parallel

0

Number of analogue inputs

2

Number of digital inputs

24

Supporting protocol for PROFIBUS

Supporting protocol for TCP/IP

Supporting protocol for INTERBUS

Supporting protocol for SUCONET

Supporting protocol for ASI

Supporting protocol for KNX

Supporting protocol for Modbus

Supporting protocol for DeviceNet

Supporting protocol for PROFINET CBA

Supporting protocol for SERCOS

Supporting protocol for LON

Supporting protocol for EtherNet/IP

Supporting protocol for Foundation Fieldbus

Supporting protocol for CAN

Supporting protocol for Data-Highway

Supporting protocol for PROFINET IO

Long-Term Evolution (LTE)

Supporting protocol for AS-Interface Safety at Work

System accessory

Redundancy

With display

Type of memory

RAM

Memory size

512kByte

Additional program memory possible

Rail mounting possible

Wall mounting/direct mounting

Suitable for safety functions

Rack-assembly possible

Front built-in possible

SIL according to IEC 61508

None

IO link master

Performance level according to EN ISO 13849-1

None

Appendant operation agent (Ex ia)

Explosion safety category for gas

None

Appendant operation agent (Ex ib)

Explosion safety category for dust

None

Width

163mm

Depth

75.9mm

Height

103.6mm

Supporting protocol for DeviceNet Safety

Supporting protocol for PROFIsafe

Supporting protocol for INTERBUS-Safety

Supporting protocol for SafetyBUS p

Supporting protocol for other bus systems

Supporting protocol for DNP3

Supporting protocol for IEC 60870

Supporting protocol for IEC 61850 Ethernet

Radio standard Bluetooth

Radio standard GSM

Radio standard UMTS

Radio standard GPRS

Radio standard Wi-Fi 802.11