  • Earthing, lightning and surge protection
  • Combined arrester for power supply systems
  • 1 KOM
  • PHOENIX

Technical specifications

System configuration DCNo
System configuration ITYes
System configuration TTNo
System configuration TN-C-SNo
System configuration TNNo
System configuration TN-CNo
System configuration TN-SNo
System configuration otherNo
Voltage protection level L-PE2.8kV
Follow current extinguishing capability25kA
Max. continuous voltage AC350V
Voltage protection level2.8kV
Max. overcurrent protection device, series connection (fuse)125A
Mounting methodDIN rail (top hat rail) 35 mm
Max. conductor cross section flexible (fine-strand)35mm²
Construction sizeOther
Max. conductor cross section solid (solid, stranded)35mm²
Max. overcurrent protection device, parallel connection (fuse)315A
Remote signallingYes
Voltage switching spark gap technologyNo
Signalling at the deviceOptic
Test classType 1
Integrated backup fuseYes
Degree of protection (IP)IP20

Related products

*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

1044388 | FLT-SEC-T1+T2-2IT-350/25-FM

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Earthing, lightning and surge protection
  • Combined arrester for power supply systems
  • 1 KOM
  • PHOENIX

Technical specifications

System configuration DC

System configuration IT

System configuration TT

System configuration TN-C-S

System configuration TN

System configuration TN-C

System configuration TN-S

System configuration other

Voltage protection level L-PE

2.8kV

Follow current extinguishing capability

25kA

Max. continuous voltage AC

350V

Voltage protection level

2.8kV

Max. overcurrent protection device, series connection (fuse)

125A

Mounting method

DIN rail (top hat rail) 35 mm

Max. conductor cross section flexible (fine-strand)

35mm²

Construction size

Other

Max. conductor cross section solid (solid, stranded)

35mm²

Max. overcurrent protection device, parallel connection (fuse)

315A

Remote signalling

Voltage switching spark gap technology

Signalling at the device

Optic

Test class

Type 1

Integrated backup fuse

Degree of protection (IP)

IP20

Related products