  • Programmable logic controllers PLC
  • Fieldbus, decentr. periphery - analogue I/O module
  • 1 KOM
  • PHOENIX

Technical specifications

Voltage type of supply voltageDC
Input, voltageYes
Input signal, configurableNo
Resolution of the analogue inputs12Bit
Input, currentNo
Input, resistance thermometerNo
Input, resistorNo
Input, thermocoupleNo
Output, currentNo
Output, voltageNo
Output signal configurableNo
Number of analogue outputs0
Analogue outputs configurableNo
Number of HW-interfaces RS-2320
Analogue inputs configurableNo
Number of interfaces PROFINET0
Number of analogue inputs1
Number of HW-interfaces industrial Ethernet0
Number of HW-interfaces serial TTY0
Number of HW-interfaces parallel0
Number of HW-interfaces other1
Number of HW-interfaces Wireless0
Number of HW-interfaces RS-4850
Number of HW-interfaces USB0
Supporting protocol for INTERBUSNo
Supporting protocol for ASINo
Supporting protocol for CANNo
Number of HW-interfaces RS-4220
Supporting protocol for PROFIBUSNo
Supporting protocol for Data-HighwayNo
Supporting protocol for TCP/IPNo
Supporting protocol for ModbusNo
Supporting protocol for EtherCATNo
Supporting protocol for KNXNo
Supporting protocol for DeviceNetNo
Supporting protocol for SUCONETNo
Supporting protocol for LONNo
Supporting protocol for PROFINET IONo
Supporting protocol for PROFINET CBANo
Supporting protocol for SERCOSNo
Supporting protocol for EtherNet/IPNo
Supporting protocol for Foundation FieldbusNo
Radio standard BluetoothNo
Supporting protocol for DeviceNet SafetyNo
Radio standard Wi-Fi 802.11No
Supporting protocol for PROFIsafeNo
Radio standard UMTSNo
Supporting protocol for AS-Interface Safety at WorkNo
Supporting protocol for other bus systemsYes
Fieldbus connection over separate bus coupler possibleYes
Radio standard GSMNo
IO link masterYes
System accessoryYes
Degree of protection (IP)IP65/IP67
Wall mounting/direct mountingNo
Supporting protocol for SafetyBUS pNo
Supporting protocol for INTERBUS-SafetyNo
Rail mounting possibleNo
Type of electric connectionOther
Radio standard GPRSNo
Suitable for safety functionsNo
Rack-assembly possibleNo
Front built-in possibleNo
Performance level according to EN ISO 13849-1None
Explosion safety category for gasNone
Width42mm
Height16.40221mm
Explosion safety category for dustNone
Depth66.5mm
Appendant operation agent (Ex ib)No
Appendant operation agent (Ex ia)No
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

2700273 | AXL E IOL AI1 U M12 R

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Programmable logic controllers PLC
  • Fieldbus, decentr. periphery - analogue I/O module
  • 1 KOM
  • PHOENIX

Technical specifications

Voltage type of supply voltage

DC

Input, voltage

Input signal, configurable

Resolution of the analogue inputs

12Bit

Input, current

Input, resistance thermometer

Input, resistor

Input, thermocouple

Output, current

Output, voltage

Output signal configurable

Number of analogue outputs

0

Analogue outputs configurable

Number of HW-interfaces RS-232

0

Analogue inputs configurable

Number of interfaces PROFINET

0

Number of analogue inputs

1

Number of HW-interfaces industrial Ethernet

0

Number of HW-interfaces serial TTY

0

Number of HW-interfaces parallel

0

Number of HW-interfaces other

1

Number of HW-interfaces Wireless

0

Number of HW-interfaces RS-485

0

Number of HW-interfaces USB

0

Supporting protocol for INTERBUS

Supporting protocol for ASI

Supporting protocol for CAN

Number of HW-interfaces RS-422

0

Supporting protocol for PROFIBUS

Supporting protocol for Data-Highway

Supporting protocol for TCP/IP

Supporting protocol for Modbus

Supporting protocol for EtherCAT

Supporting protocol for KNX

Supporting protocol for DeviceNet

Supporting protocol for SUCONET

Supporting protocol for LON

Supporting protocol for PROFINET IO

Supporting protocol for PROFINET CBA

Supporting protocol for SERCOS

Supporting protocol for EtherNet/IP

Supporting protocol for Foundation Fieldbus

Radio standard Bluetooth

Supporting protocol for DeviceNet Safety

Radio standard Wi-Fi 802.11

Supporting protocol for PROFIsafe

Radio standard UMTS

Supporting protocol for AS-Interface Safety at Work

Supporting protocol for other bus systems

Fieldbus connection over separate bus coupler possible

Radio standard GSM

IO link master

System accessory

Degree of protection (IP)

IP65/IP67

Wall mounting/direct mounting

Supporting protocol for SafetyBUS p

Supporting protocol for INTERBUS-Safety

Rail mounting possible

Type of electric connection

Other

Radio standard GPRS

Suitable for safety functions

Rack-assembly possible

Front built-in possible

Performance level according to EN ISO 13849-1

None

Explosion safety category for gas

None

Width

42mm

Height

16.40221mm

Explosion safety category for dust

None

Depth

66.5mm

Appendant operation agent (Ex ib)

Appendant operation agent (Ex ia)